loader image

Commercial & Industrial ESS Battery​

Power cuts, peak load charges, diesel generator cost, and unstable supply can create real problems for businesses. In a factory, even a short power interruption can stop machines. In a commercial building, backup failure can affect lifts, lighting, security, and daily operations. At telecom sites or warehouses, power reliability is not optional.That is where Ipower’s Commercial & Industrial ESS solutions come in.

As an Energy Storage System Supplier, Ipower provides lithium-based storage solutions for factories, commercial buildings, telecom sites, institutions, warehouses, renewable energy projects, and industrial facilities. These systems help businesses store electricity from solar, wind, grid supply, or hybrid power sources and use it when required.

Salient Features

Ipower batteries are designed to support a wide range of modern energy applications, delivering reliable and efficient power for commercial and industrial needs. They are suitable for solar energy storage, wind power systems, UPS backup solutions, and telecommunication infrastructure, ensuring stable and continuous power supply.

High Energy
Efficiency

Ipower ESS batteries are designed to store and deliver energy with better efficiency, so businesses can use more of the power they generate or receive. This is useful for solar projects, commercial buildings, factories, and industrial sites where energy loss directly affects operating cost. A high-efficiency Energy Storage Battery helps make backup power and renewable energy storage more practical for daily business use.

Power
Saving

A properly selected Energy Storage System can help businesses reduce unnecessary power wastage and manage energy use more smartly. Stored energy can support important loads during peak demand, grid failure, or low solar generation hours. For sites that depend heavily on diesel generators or face high electricity costs, Ipower ESS solutions can help improve power usage and reduce long-term energy expenses.

No
Maintenance

Ipower lithium-based ESS batteries need far less maintenance compared to many traditional battery systems. There is no regular water topping, acid handling, or frequent manual checking like old battery setups. This makes the system easier to manage for factories, telecom sites, institutions, warehouses, and commercial buildings where teams need reliable backup without regular battery-side maintenance work.

protechtion
Advanced BMS
Protection

Every Ipower ESS battery comes with an advanced Battery Management System that monitors key battery conditions like voltage, current, temperature, charge level, discharge performance, and battery health. This protection helps the battery operate safely and supports longer service life. For commercial and industrial users, advanced BMS protection is important because large backup systems must stay stable under real working loads.

Available Models

120V100Ah

LFP Prismatic Cell – 3.2V 100 Ah

38S 100A- BMS in single module (Integrated)

120V 100Ah Battery Pack – Built using high-performance LFP Prismatic Cells (3.2V, 100Ah), designed for reliable energy storage and long cycle life.

Description Parameters
Battery Model 120V100Ah
Nominal voltage (V) 121.6 V
Capacity 100 Ah
Cell Chemistry & Cell Type LFP Prismatic Cell – 3.2V 100 Ah
Usable capacity of AH 95 %
RBMS/BMS Rating 38S 100A- BMS in single module (Integrated)
Operating voltage range (V) 104.5 V ~ 136.8 V
Standard Charging current (A) 0.7 C
Standard Discharging current (A) 0.8 C
DOD% 80% (Minimum)
CAN Enabled
RS485/RS232 Enabled
Charge Temperature 0 ~ 55°C
Discharge Temperature -15 ~ 65°C
Storage temperature 25 ~ 30°C
Cycle Life 3000 Cycles @80% DOD & at 25±5°C

120V200Ah

LFP Prismatic Cell – 3.2V 100 Ah

38S 100A- BMS in single module (Integrated)

120V 200Ah Battery Pack – Built using high-performance LFP Prismatic Cells (3.2V, 100Ah), designed for reliable energy storage and long cycle life.

Description Parameters
Battery Model 120V200Ah
Nominal voltage (V) 121.6 V
Capacity 100 Ah
Cell Chemistry & Cell Type LFP Prismatic Cell – 3.2V 100 Ah
Usable capacity of AH 95 %
RBMS/BMS Rating 38S 100A- BMS in single module (Integrated)
Operating voltage range (V) 104.5 V ~ 136.8 V
Standard Charging current (A) 0.7 C
Standard Discharging current (A) 0.8 C
DOD% 80% (Minimum)
CAN Enabled
RS485/RS232 Enabled
Charge Temperature 0 ~ 55°C
Discharge Temperature -15 ~ 65°C
Storage temperature 25 ~ 30°C
Cycle Life 3000 Cycles @80% DOD & at 25±5°C

192V50Ah

LFP Prismatic Cell – 3.2V 50Ah

3000 Cycles @80% DOD & at 25±5°C

192V 50Ah Battery Pack – Built using high-performance LFP Prismatic Cells (3.2V, 50Ah), designed for reliable energy storage and long cycle life.

Description Parameters
Battery Model 192V50Ah
Nominal Voltage (V) 192V
Capacity 50Ah
Cell Chemistry & Cell Type LFP Prismatic Cell – 3.2V 50Ah
Usable Capacity of AH 95 %
RBMS/BMS Rating 192V DC-50A Integrated
Operating Voltage Range (V) 165 V ~ 216 V
Standard Charging Current (A) 0.5 C
Standard Discharging Current (A) 0.5 C
DOD% 80% (Minimum)
CAN Enabled
RS485/RS232 Enabled
Charge Temperature 0 ~ 55°C
Discharge Temperature -15 ~ 65°C
Storage Temperature 25 ~ 30°C
Cycle Life 3000 Cycles @80% DOD & at 25±5°C

192V100Ah

LFP Prismatic Cell – 3.2V 100Ah

3000 Cycles @80% DOD & at 25±5°C

192V 100Ah Battery Pack – Built using high-performance LFP Prismatic Cells (3.2V, 100Ah), designed for reliable energy storage and long cycle life.

Description Parameters
Battery Model 192V100Ah
Nominal Voltage (V) 192V
Capacity 100Ah
Cell Chemistry & Cell Type LFP Prismatic Cell – 3.2V 100Ah
Usable Capacity of AH 95 %
RBMS/BMS Rating 192V DC-100A
Operating Voltage Range (V) 165 V ~ 216 V
Standard Charging Current (A) 0.5 C
Standard Discharging Current (A) 0.5 C
DOD% 80% (Minimum)
CAN Enabled
RS485/RS232 Enabled
Charge Temperature 0 ~ 55°C
Discharge Temperature -15 ~ 65°C
Storage Temperature 25 ~ 30°C
Cycle Life 3000 Cycles @80% DOD & at 25±5°C

240V100Ah

LFP Prismatic Cell – 3.2V 100Ah

3000 Cycles @80% DOD & at 25±5°C

240V 100Ah Battery Pack – Built using high-performance LFP Prismatic Cells (3.2V, 100Ah), designed for reliable energy storage and long cycle life.

Description Parameters
Battery Model 240V100Ah
Nominal Voltage (V) 240V
Capacity 100Ah
Cell Chemistry & Cell Type LFP Prismatic Cell – 3.2V 100Ah
Usable Capacity of AH 95 %
RBMS/BMS Rating 75S Integrated RBMS
Operating Voltage Range (V) 206 V ~ 273 V
Standard Charging Current (A) 0.7 C
Standard Discharging Current (A) 0.8 C
DOD% 80% (Minimum)
CAN Enabled + HMI Screen Display
RS485/RS232 Enabled
Charge Temperature 0 ~ 55°C
Discharge Temperature -15 ~ 65°C
Storage Temperature 25 ~ 30°C
Cycle Life 3000 Cycles @80% DOD & at 25±5°C

240V200Ah

LFP Prismatic Cell – 3.2V 100Ah

3000 Cycles @80% DOD & at 25±5°C

240V 200Ah Battery Pack – Built using high-performance LFP Prismatic Cells (3.2V, 100Ah), designed for reliable energy storage and long cycle life.

Description Parameters
Battery Model 240V200Ah
Nominal Voltage (V) 240V
Capacity 200Ah
Cell Chemistry & Cell Type LFP Prismatic Cell – 3.2V 100Ah
Usable Capacity of AH 95 %
RBMS/BMS Rating 240V/250A RBMS
Operating Voltage Range (V) 206 V ~ 273 V
Standard Charging Current (A) 0.7 C
Standard Discharging Current (A) 0.8 C
DOD% 80% (Minimum)
CAN Enabled + HMI Screen Display
RS485/RS232 Enabled
Charge Temperature 0 ~ 55°C
Discharge Temperature -15 ~ 65°C
Storage Temperature 25 ~ 30°C
Cycle Life 3000 Cycles @80% DOD & at 25±5°C

360V100Ah

LFP Prismatic Cell – 3.2V 100Ah

3000 Cycles @80% DOD & at 25±5°C

360V 100Ah Battery Pack – Built using high-performance LFP Prismatic Cells (3.2V, 100Ah), designed for reliable energy storage and long cycle life.

Description Parameters
Battery Model 360V100Ah
Nominal Voltage (V) 358V
Capacity 100Ah
Cell Chemistry & Cell Type LFP Prismatic Cell – 3.2V 100Ah
Usable Capacity of AH 95 %
RBMS/BMS Rating 358.4VDC - 125A
Operating Voltage Range (V) 308 V ~ 403 V
Standard Charging Current (A) 0.7 C
Standard Discharging Current (A) 0.8 C
DOD% 80% (Minimum)
CAN Enabled + HMI Screen Display
RS485/RS232 / Ethernet Enabled + Ethernet
Charge Temperature 0 ~ 55°C
Discharge Temperature -15 ~ 65°C
Storage Temperature 25 ~ 30°C
Cycle Life 3000 Cycles @80% DOD & at 25±5°C

360V200Ah

LFP Prismatic Cell – 3.2V 100Ah

3000 Cycles @80% DOD & at 25±5°C

360V 200Ah Battery Pack – Built using high-performance LFP Prismatic Cells (3.2V, 100Ah), designed for reliable energy storage and long cycle life.

Description Parameters
Battery Model 360V200Ah
Nominal Voltage (V) 358V
Capacity 200Ah
Cell Chemistry & Cell Type LFP Prismatic Cell – 3.2V 100Ah
Usable Capacity of AH 95 %
RBMS/BMS Rating 358.4VDC - 250A
Operating Voltage Range (V) 308 V ~ 403 V
Standard Charging Current (A) 0.7 C
Standard Discharging Current (A) 0.8 C
DOD% 80% (Minimum)
CAN Enabled + HMI Screen Display
RS485/RS232 / Ethernet Enabled + Ethernet
Charge Temperature 0 ~ 55°C
Discharge Temperature -15 ~ 65°C
Storage Temperature 25 ~ 30°C
Cycle Life 3000 Cycles @80% DOD & at 25±5°C

480V100Ah

LFP Prismatic Cell – 3.2V 100Ah

3000 Cycles @80% DOD & at 25±5°C

480V 100Ah Battery Pack – Built using high-performance LFP Prismatic Cells (3.2V, 100Ah), designed for reliable energy storage and long cycle life.

Description Parameters
Battery Model 480V100Ah
Nominal Voltage (V) 480V
Capacity 100Ah
Cell Chemistry & Cell Type LFP Prismatic Cell – 3.2V 100Ah
Usable Capacity of AH 95 %
RBMS/BMS Rating 480V / 125A RBMS
Operating Voltage Range (V) 412 V ~ 540 V
Standard Charging Current (A) 0.7 C
Standard Discharging Current (A) 0.8 C
DOD% 80% (Minimum)
CAN Enabled + HMI Screen Display
RS485/RS232 Enabled
Charge Temperature 0 ~ 55°C
Discharge Temperature -15 ~ 65°C
Storage Temperature 25 ~ 30°C
Cycle Life 3000 Cycles @80% DOD & at 25±5°C

480V200Ah

LFP Prismatic Cell – 3.2V 100Ah

3000 Cycles @80% DOD & at 25±5°C

480V 200Ah Battery Pack – Built using high-performance LFP Prismatic Cells (3.2V, 100Ah), designed for reliable energy storage and long cycle life.

Description Parameters
Battery Model 480V200Ah
Nominal Voltage (V) 480V
Capacity 200Ah
Cell Chemistry & Cell Type LFP Prismatic Cell – 3.2V 100Ah
Usable Capacity of AH 95 %
RBMS/BMS Rating 480/250A RBMS
Operating Voltage Range (V) 412 V ~ 540 V
Standard Charging Current (A) 0.7 C
Standard Discharging Current (A) 0.8 C
DOD% 80% (Minimum)
CAN Enabled + HMI Screen Display
RS485/RS232 Enabled
Charge Temperature 0 ~ 55°C
Discharge Temperature -15 ~ 65°C
Storage Temperature 25 ~ 30°C
Cycle Life 3000 Cycles @80% DOD & at 25±5°C